YD30 acceleration sensor
| Parameter | Specification |
|---|---|
| Sensitivity | 100 mV/g; other values customizable |
| Frequency response | 0–10 kHz (±3 dB) |
| Amplitude nonlinearity | ≤ ±1% |
| Transverse sensitivity ratio | ≤ 5% |
| Excitation voltage | +18 to +28 VDC, constant-current supply |
| Excitation current | 2–10 mA |
| Maximum shock | 2000 g |
| Operating temperature | −40 to +85°C |
| Protection | IP68 |
| Housing | 304 stainless steel |
| Output connection | Two-pin circular connector with 3 m cable |
| Default mounting thread | M6×1 |
YD30W acceleration and temperature sensor
| Parameter | Specification |
|---|---|
| Explosion-protection marking | Ex ia IIC T6 Ga |
| Temperature range | 0–100°C |
| Sensitivity | 100 mV/g; other values customizable |
| Frequency response | 0–10 kHz (±3 dB) |
| Amplitude nonlinearity | ≤ ±1% |
| Transverse sensitivity ratio | ≤ 5% |
| Excitation voltage | +18 to +28 VDC, constant-current supply |
| Excitation current | 2–10 mA |
| Maximum shock | 2000 g |
| Operating temperature | −40 to +85°C |
| Protection | IP68 |
| Housing | 304 stainless steel |
| Output connection | Four-pin circular connector with 3 m cable |
| Default mounting thread | M6×1 |
YD30 differences across documented sources
| Parameter | Product catalog edition | YD30 product manual | CZ900 system manual |
|---|---|---|---|
| Frequency response | 0–10 kHz (±3 dB) | 0–2 kHz (−3 dB) | 0–10 kHz (−3 dB) |
| Protection | IP68 | IP64 | IP64 |
| Maximum shock | 2000 g | 10000 g | 10000 g |
These are known differences, not a statement that every other parameter agrees. The hardware versions and currently applicable values have not been confirmed. Keep each source's specifications separate and confirm the required configuration; do not combine them into a single specification set. This difference table concerns YD30 only and does not apply to YD30W.