Product reference

YD240 Speed Transmitter

Speed-signal input, current or RS-485 output and pulses-per-revolution selection.

On this page

Technical specifications

Parameter Specification
Input signal frequency response, as printed 0.4–40 kHz; lower-end unit unconfirmed
AC signal input > 300 mV
Measurement error ±1% FSO
Operating temperature −20 to +75°C
Supply +24 VDC
Resolution 0.05% FS
Protection IP44
Dimensions 79 mm L × 30 mm W × 56 mm H

Ordering options

YD240-A□□-B□□-C□□-D□□

Parameter Specification
A — Range 01: 0–1000 r/min; 02: 0–2000 r/min; 03: 0–3000 r/min; …
B — Input sensor 01: YD9800 eddy current sensor; 02: YD60 passive magnetoelectric sensor; 03: YD62 Hall-effect speed sensor
C — Pulses per revolution 01: 1 pulse; 02: 2 pulses; 03: 3 pulses; …
D — Output 01: 4–20 mA; 02: RS-485

Only explicitly printed codes are listed. Ellipses do not establish omitted intermediate codes.

Input-frequency limitation

The input response is printed as 0.4–40 kHz without a separate unit at the lower endpoint. Neither 0.4 Hz nor 0.4 kHz is established as the lower limit by this reference.