Product reference
GZW50-150 Intrinsically Safe Mining Vibration and Temperature Transmitter
GZW50/150 catalog ratings and ordering codes for separate vibration and temperature outputs.
On this page
Catalog specifications; confirm the ordered configuration and applicable explosion-protection documentation.
Technical specifications
| Parameter | Specification |
|---|---|
| Catalog model name | GZW50/150 |
| Explosion-protection marking | Ex ib I Mb |
| Safety-mark identifier | MFB210431 |
| Outputs | 4–20 mA, four-wire; one vibration and one temperature output |
| Frequency response | 10–1000 Hz |
| Operating temperature | −20 to +85°C |
| Measurement error | ≤ ±5% FSO |
| Supply | +24 VDC |
| Positive measurement direction | From the base toward the sensor |
| Maximum shock | 2000 g |
| Protection | IP68 |
| Output impedance | < 500 Ω |
| Housing | 304 stainless steel |
Ordering options
GZW50/150-A□□-B□□-C□□-D□□-E□□-F□□-G□□
| Parameter | Specification |
|---|---|
| A — Measurement type | 01: V (velocity); 02: G (acceleration); 03: D (displacement) |
| B — Vibration range | V: 01 = 0–10 mm/s; 02 = 0–20 mm/s; …; 09 = 0–90 mm/s; G: 01 = 0–10 g; 02 = 0–20 g; …; 09 = 0–90 g; D: 01 = 0–100 μm; 02 = 0–200 μm; …; 09 = 0–900 μm |
| C — Mounting | 01: M10×1.5; 02: M8×1.25; 03: magnetic base; 04: custom |
| D — Cable length | 01: 1 m; 02: 2 m; 03: 3 m; …; 10: 10 m |
| E — Connection | 00(K): direct cable; 01(K): circular connector. K denotes optional armor. |
| F — Temperature range | 01: 0–100°C; 02: 0–150°C; 03: −50 to +100°C; 04: −50 to +150°C; 05: other |
| G — Temperature rod insertion depth | 00: label unresolved; 01: 10 mm; 02: 20 mm; 03: 30 mm; …; 10: 100 mm |
Only explicitly printed codes are listed. Ellipses do not confirm the omitted intermediate codes.
Dimension drawing labels
5/8-24UNEF circular connector; overall height 83.50; lower height 69.00; outside diameter φ34.00; base width 32.50; mounting thread M8×1.25.
These are the legible labels in the catalog drawing. The bare numbers do not each carry a unit. Their dimension datums and applicability to the selected configuration require confirmation; do not apply one illustrated geometry to every ordering option.
Selection limitations
The description for insertion-depth code 00 is not confirmed. Obtain the construction corresponding to this code before specifying it. The catalog identifier and explosion-protection marking are reproduced as source statements; this reference does not establish current certificate validity.