Product reference
CZ9930 Eddy Current Displacement and Temperature Sensor
Combined displacement and temperature outputs, ordering codes and unresolved temperature-drift channel assignment.
On this page
Catalog specifications; confirm the ordered configuration and applicable explosion-protection documentation.
Technical specifications
| Parameter | Specification |
|---|---|
| Explosion-protection marking | Ex ia IIB T6 Ga |
| Resolution | 0.05% FS |
| Frequency response | 0–20 kHz |
| Linearity error | ≤ ±1% FSO |
| Temperature drift, first entry | ≤ 0.06%/°C |
| Operating temperature | −40 to +150°C |
| Supply | +24 VDC |
| Temperature drift, second entry | ≤ 0.03%/°C |
| Temperature measurement range | −50 to +200°C, optional |
| Displacement output | 0–5 V |
| Temperature output | 0–5 V |
| Protection | IP67 |
| Housing | 304 stainless steel; custom option |
| Cable armor | φ8.5 stainless steel corrugated tube |
Ordering options
CZ9930-A□□-B□□-C□□-D□□-E□□-F□□-G□□
| Parameter | Specification |
|---|---|
| A — Probe diameter | 01: φ5; 02: φ8; 03: φ11; 04: φ25; 05: φ50 |
| B — Range | 01: 0–1 mm; 02: 0–2 mm; 03: 0–4 mm; 04: 0–12 mm; 05: 0–25 mm |
| C — Thread | 01: M8×1; 02: M10×1; 03: M14×1.5; 04: M30×2; 05: custom |
| D — Mounting | 01: standard; 02: reverse; 03: side cable exit; 04: flange |
| E — Unthreaded length | 00: 00 mm; 01: 01 mm; 02: 02 mm; …; 10: 10 mm |
| F — Overall housing length | 20: 20 mm; 50: 50 mm; …; 250: 250 mm |
| G — Probe cable + extension cable | 01: 3 + 0 m; 02: 1 + 4 m; 03: 3 + 6 m |
Only the printed codes are listed. An ellipsis in the catalog does not establish the omitted intermediate ordering codes.
Temperature-drift limitation
The catalog contains two temperature-drift values, ≤ 0.06%/°C and ≤ 0.03%/°C, without assigning either to a channel. Neither value can be identified as the displacement-channel or temperature-channel specification from this reference.