Product reference

CZ9920 High-Accuracy Digital Eddy Current Sensor

Digital eddy current sensor specifications, probe options and conditioner range differences.

On this page

Catalog specifications; confirm the ordered configuration and applicable explosion-protection documentation.

Technical specifications

Parameter Specification
Explosion-protection marking Ex ia IIB T6 Ga
Resolution 0.01% FS
Frequency response 0–2 kHz
Linearity error ≤ ±0.3% FSO, best case
Temperature drift ≤ 0.03%/°C
Operating temperature −40 to +150°C
Supply +24 VDC
Digital interfaces RS-485; optional RJ-45
Analog outputs 0–5 V; 0–10 V
Digital outputs Modbus RTU; TCP/IP
Protection IP68
Housing 316 stainless steel; custom material available

Probe measurement ranges

Probe diameter (mm) Linear range (mm) Linearity error Minimum target dimension (mm; terminology unconfirmed)
φ5 1 ≤ ±0.3% φ15
φ8 2 ≤ ±0.3% φ25
φ11 4 ≤ ±0.5% φ35
φ25 12 ≤ ±0.5% φ50
φ50 25 ≤ ±1% φ100
φ100 50 ≤ ±1% φ200

The catalog's general linearity figure and the diameter-specific errors are separate specifications. Use the error for the selected probe; do not apply the single general figure to every range. The original heading translated here as minimum target dimension has unclear terminology; confirm its meaning before specifying a target surface.

Probe ordering options

CZ9920-A□□-B□□-C□□-D□□-E□□-F□□-G□□

Parameter Specification
A — Probe diameter 01: φ5; 02: φ8; 03: φ11; 04: φ25; 05: φ50; 06: φ100
B — Thread 01: M8×1; 02: M10×1; 03: M14×1.5; 04: M30×2; 05: custom
C — Mounting 01: standard; 02: reverse; 03: side cable exit; 04: flange
D — Unthreaded length 00: 00 mm; 10: 10 mm; 20: 20 mm; …; 100: 100 mm
E — Overall housing length 20: 20 mm; 50: 50 mm; …; 250: 250 mm
F — Probe cable + extension cable 01: 3 + 0 m; 02: 1 + 4 m; 03: 3 + 6 m
G — Armor 00: armored; 01: unarmored

Only the printed codes are listed. An ellipsis in the catalog does not establish the omitted intermediate ordering codes.

Conditioner ordering options

CWY-DO-A□□-B□□-C□□

Parameter Specification
A — Range 01: 0–1 mm; 02: 0–2 mm; 03: 0–4 mm; 04: 0–15 mm; 05: 0–30 mm; 06: 0–50 mm; 07: custom
B — System cable length 03: 3 m system; 05: 5 m system; 09: 9 m system
C — Output 01: 0–5 V; 02: 0–10 V; 03: Modbus RTU; 04: TCP/IP

Only the printed codes are listed. An ellipsis in the catalog does not establish the omitted intermediate ordering codes.

Range matching and selection limitations

The probe measurement table lists 12 mm and 25 mm, while the corresponding positions in the conditioner ordering table list 0–15 mm and 0–30 mm. Both values are retained; a matching probe–conditioner combination is not established by these tables. Confirm the required pairing before ordering.

The selection drawing identifies the probe, probe cable, extension cable and armor by the ordering-table letters. It does not specify additional universal fixed dimensions. The conditioner designation is printed as CWY-DO; whether the final character is the letter O or the digit zero remains unconfirmed.