Product reference

CZ9400 Flameproof Integrated Vibration Transmitter

Acceleration, velocity and displacement options with electrical, mechanical and ordering specifications.

On this page

Catalog specifications; confirm the ordered configuration and applicable explosion-protection documentation.

Technical specifications

Parameter Specification
Explosion-protection marking, as printed Exd II BT 6 Ga
Measurement types Vibration acceleration, velocity or displacement
Output 4–20 mA, two-wire
Acceleration frequency response 2–2000 Hz
Velocity frequency response 5–1000 Hz
Displacement frequency response 10–2000 Hz
Operating temperature −40 to +85°C
Measurement error ≤ ±5% FSO
Supply +24 VDC
Maximum shock 2000 g
Piezoelectric material PZT-5
Protection IP68
Weight Approximately 450 g
Housing 304 stainless steel sensor; cast-aluminum explosion-proof enclosure

Ordering options

CZ9400-A□□-B□□-C□□-D□□

Parameter Specification
A — Measurement type 01: V (velocity); 02: G (acceleration); 03: D (displacement)
B — Range V: 01 = 0–10 mm/s; 02 = 0–20 mm/s; 03 = 0–30 mm/s; …; G: 01 = 0–10 g; 02 = 0–20 g; 03 = 0–30 g; …; D: 01 = 0–100 μm; 02 = 0–200 μm; 03 = 0–300 μm; …
C — Mounting 01: M10×1.5; 02: M8×1.25; 03: custom
D — Electrical entry 01: M20×1.5; 02: NPT1/2; 03: G1/2

Only explicitly printed codes are listed. Ellipses do not confirm the omitted intermediate codes.

Dimension drawing labels

Outside diameters φ73, φ52 and φ34; overall height 128.2; lower height 43; flameproof joint M67×1.5-6g; mounting thread M10×1.5-6g.

These are the legible labels in the catalog drawing. The bare numbers do not each carry a unit. Their dimension datums and applicability to the selected configuration require confirmation; do not apply one illustrated geometry to every ordering option.