Product reference

YD69 Forward and Reverse Rotation Speed Sensor

Speed sensing electrical specifications, detection distances and mechanical ordering options.

On this page

Technical specifications

Parameter Specification
Frequency response 0–20 kHz
Supply +5 to +26 VDC
Operating temperature −40 to +120°C
Load resistance ≥ 1 kΩ
Load capacity 20 mA maximum
Current consumption ≤ 10 mA, excluding load current
Detection distance for A3 steel or electrical steel 1–4 mm
Detection distance for magnetic steel 5–10 mm; consistent magnetic polarity during installation
Gear module m ≥ 1; material note names A3 steel, electrical steel and 120°C
Output Rectangular wave; high level U − 0.7 V, where U is supply voltage; low level < 0.1 V
Protection IP68
Supply reverse-polarity protection Provided
Output short-circuit protection Provided
Dielectric strength 1000 V, 50 Hz, 1 minute between channel and housing

Ordering options

YD69-A□□-B□□-C□□-D□□

Parameter Specification
A — Thread 01: M16×1; 02: custom
B — Housing length 50: 50 mm; 80: 80 mm; …; 120: 120 mm
C — Connection 00(K): direct cable; 01(K): circular connector. K denotes optional armor.
D — Cable length 01: 1 m; 02: 2 m; …; 09: 9 m

Only explicitly printed codes are listed. Ellipses do not establish omitted intermediate codes.

Gear-material note

The gear-module entry includes 120°C inside the parenthetical material description. Its precise applicability is unclear, so it is not assigned to an additional operating condition in this reference.