Product reference

YD62 Explosion-Protected Speed Sensor

Speed sensing electrical specifications, detection distances and mechanical ordering options.

On this page

Catalog specifications; confirm the ordered configuration and applicable explosion-protection documentation.

Technical specifications

Parameter Specification
Explosion-protection marking, as printed Exia ll BT6 Ga
Frequency response 0–20 kHz
Supply +5 to +26 VDC
Operating temperature −40 to +120°C
Load resistance ≥ 1 kΩ
Output impedance ≤ 47 Ω
Load capacity 20 mA maximum
Current consumption ≤ 10 mA, excluding load current
Detection distance for A3 steel or electrical steel 1–4 mm
Detection distance for magnetic steel 5–10 mm; consistent magnetic polarity during installation
Gear module m ≥ 1; material note names A3 steel, electrical steel and 120°C
Output Rectangular wave; high level U − 0.7 V, where U is supply voltage; low level < 0.1 V
Protection IP68
Supply reverse-polarity protection Provided
Output short-circuit protection Provided
Dielectric strength 1000 V, 50 Hz, 1 minute between channel and housing

Ordering options

YD62-A□□-B□□-C□□-D□□

Parameter Specification
A — Thread 01: M10×1; 02: M16×1; 03: M12×1; 04: M14×1.5; 05: custom
B — Housing length 50: 50 mm; 80: 80 mm; …; 120: 120 mm
C — Connection 00(K): direct cable; 01(K): circular connector. K denotes optional armor.
D — Cable length 01: 1 m; 02: 2 m; …; 09: 9 m

Only explicitly printed codes are listed. Ellipses do not establish omitted intermediate codes.

Gear-material note

The gear-module entry includes 120°C inside the parenthetical material description. Its precise applicability is unclear, so it is not assigned to an additional operating condition in this reference.