Product reference

YD280 Digital Vibration Transmitter

RS-485 vibration measurement, networking, optional relay output and configuration codes.

On this page

Technical specifications

Parameter Specification
Measurement types Vibration acceleration, velocity or displacement
Output RS-485
Sensor type Piezoelectric acceleration
Acceleration frequency range, as printed 10–5 kHz; lower-end unit unconfirmed
Velocity and displacement frequency range, as printed 10–1 kHz; lower-end unit unconfirmed
Vibration resolution 12 bit
Sampling rate 12.8 kHz
Ambient temperature −40 to +85°C
Linearity error 0.2% FSO
Supply +12 to +24 VDC
Data interface RS-485 industrial bus
Maximum sensors per network 64
Alarm contact rating 28 VDC, 3 A
Relay state Normally open
Maximum shock 2000 g
Piezoelectric material PZT-5
Protection IP67
Weight Approximately 450 g
Dynamic range < 70 dB; inequality retained as printed
Housing 304 stainless steel

Ordering options

YD280-A□□-B□□-C□□-D□□-E□□-F□□

Parameter Specification
A — Measurement type 01: V (velocity); 02: G (acceleration); 03: D (displacement)
B — Vibration range V: 01 = 0–10 mm/s; 02 = 0–20 mm/s; …; 09 = 0–90 mm/s; G: 01 = 0–10 g; 02 = 0–20 g; …; 09 = 0–90 g; D: 01 = 0–100 μm; 02 = 0–200 μm; …; 09 = 0–900 μm
C — Mounting 01: M10×1.5; 02: M8×1.25; 03: magnetic base; 04: custom
D — Cable length 01: 1 m; 02: 2 m; …; 10: 10 m
E — Connection 00(K): direct cable; 01(K): circular connector. K denotes optional armor.
F — Relay 00: no relay output; 01: relay output

Only explicitly printed codes are listed. Ellipses do not confirm the omitted intermediate codes.

Dimension drawing labels

5/8-24UNEF circular connector; overall height 83.50; lower height 69.00; outside diameter φ34.00; base width 32.50; mounting thread M8×1.25.

These are the legible labels in the catalog drawing. The bare numbers do not each carry a unit. Their dimension datums and applicability to the selected configuration require confirmation; do not apply one illustrated geometry to every ordering option.

Frequency and dynamic-range limitations

The frequency-range lower endpoints are printed without their own units. A lower limit of 10 Hz has not been confirmed by this reference. The dynamic range is explicitly printed as less than 70 dB; it has not been changed to a greater-than specification.