Technical specifications
| Parameter | Specification |
|---|---|
| Explosion-protection marking | EX ia IIC T4 Ga |
| Acceleration frequency response | 0.5 Hz–10 kHz |
| Velocity frequency response | 10–1000 Hz |
| Dynamic acceleration signal frequency response | 2–2000 Hz |
| Operating temperature | −40 to +85°C |
| Measurement error | ≤ ±5% FSO |
| Supply | +12 to +24 VDC |
| Current output | 4–20 mA, velocity |
| Voltage output | Dynamic acceleration, raw signal |
| Insulation resistance, as printed | > 100 mΩ; unit unconfirmed |
| Wiring | Two loop outputs |
| Maximum shock | 2000 g |
| Piezoelectric material | PZT-5 |
| Protection | IP68 |
| Housing | 304 stainless steel |
Ordering options
CZ9300XL-A□□-B□□-C□□-D□□-E□□-F□□
| Parameter | Specification |
|---|---|
| A — Measurement type | 01: V (velocity); 02: G (acceleration) |
| B — Vibration range | V: 01 = 0–10 mm/s; 02 = 0–20 mm/s; 03 = 0–30 mm/s; …; G: 01 = 0–10 g; 02 = 0–20 g; 03 = 0–30 g; … |
| C — Dynamic signal frequency-response range, as headed in catalog | 20: 20 mv/g; 100: 100 mv/g; 200: 200 mv/g |
| D — Mounting | 01: M10×1.5; 02: M8×1.25; 03: magnetic base; 04: custom |
| E — Cable length | 01: 1 m; 02: 2 m; 03: 3 m; …; 10: 10 m |
| F — Connection | 00(K): direct cable; 01(K): circular connector. K denotes optional armor. |
Only explicitly printed codes are listed. Ellipses do not confirm the omitted intermediate codes.
Dimension drawing labels
5/8-24UNEF circular connector; overall height 63.00; lower height 47.20; outside diameter φ24.00; base width 27.00; mounting thread M8×1.25.
These are the legible labels in the catalog drawing. The bare numbers do not each carry a unit. Their dimension datums and applicability to the selected configuration require confirmation; do not apply one illustrated geometry to every ordering option.
Ordering and unit limitations
Ordering field C is headed dynamic signal frequency-response range, but the values have mv/g units. The heading and units are inconsistent; this reference does not replace them with an assumed frequency or sensitivity specification. Insulation resistance is printed as > 100 mΩ and has not been changed to MΩ. The technical table specifies velocity for the current output, while the ordering table also offers acceleration. Confirm the actual output configuration for the selected code.