Product reference

CZ9300XL Explosion-Protected Dual-Output Vibration Transmitter

Velocity current output and dynamic acceleration output, with documented ordering ambiguities.

On this page

Catalog specifications; confirm the ordered configuration and applicable explosion-protection documentation.

Technical specifications

Parameter Specification
Explosion-protection marking EX ia IIC T4 Ga
Acceleration frequency response 0.5 Hz–10 kHz
Velocity frequency response 10–1000 Hz
Dynamic acceleration signal frequency response 2–2000 Hz
Operating temperature −40 to +85°C
Measurement error ≤ ±5% FSO
Supply +12 to +24 VDC
Current output 4–20 mA, velocity
Voltage output Dynamic acceleration, raw signal
Insulation resistance, as printed > 100 mΩ; unit unconfirmed
Wiring Two loop outputs
Maximum shock 2000 g
Piezoelectric material PZT-5
Protection IP68
Housing 304 stainless steel

Ordering options

CZ9300XL-A□□-B□□-C□□-D□□-E□□-F□□

Parameter Specification
A — Measurement type 01: V (velocity); 02: G (acceleration)
B — Vibration range V: 01 = 0–10 mm/s; 02 = 0–20 mm/s; 03 = 0–30 mm/s; …; G: 01 = 0–10 g; 02 = 0–20 g; 03 = 0–30 g; …
C — Dynamic signal frequency-response range, as headed in catalog 20: 20 mv/g; 100: 100 mv/g; 200: 200 mv/g
D — Mounting 01: M10×1.5; 02: M8×1.25; 03: magnetic base; 04: custom
E — Cable length 01: 1 m; 02: 2 m; 03: 3 m; …; 10: 10 m
F — Connection 00(K): direct cable; 01(K): circular connector. K denotes optional armor.

Only explicitly printed codes are listed. Ellipses do not confirm the omitted intermediate codes.

Dimension drawing labels

5/8-24UNEF circular connector; overall height 63.00; lower height 47.20; outside diameter φ24.00; base width 27.00; mounting thread M8×1.25.

These are the legible labels in the catalog drawing. The bare numbers do not each carry a unit. Their dimension datums and applicability to the selected configuration require confirmation; do not apply one illustrated geometry to every ordering option.

Ordering and unit limitations

Ordering field C is headed dynamic signal frequency-response range, but the values have mv/g units. The heading and units are inconsistent; this reference does not replace them with an assumed frequency or sensitivity specification. Insulation resistance is printed as > 100 mΩ and has not been changed to MΩ. The technical table specifies velocity for the current output, while the ordering table also offers acceleration. Confirm the actual output configuration for the selected code.